Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    Firmware Version Reference and Download

    Baseline Controller Platform

    PDF es:

    BaseStation 3200


    Read me first, before updating

    Before updating the firmware on a BaseStation 3200 irrigation controller, you must check the hardware version. If the hardware version is 2.0 or lower, you can update to V16.6, but no higher. If you have questions, contact Baseline Support (866.294.5847).

    To check the hardware version on a BaseStation 3200 irrigation controller:

    1.  On the BaseStation 3200 controller or in LiveView, go to the Advanced dial position.

    2.  Choose the System Settings option.

    3.  Find the hardware version number as shown in the illustration below.


    Important

    We always recommend that you perform a system backup before you update the BaseStation 3200 firmware. If you experience issues with the firmware update, you can restore your BaseStation 3200 to the previous configuration.


    Additionally, we recommend that you use a USB drive to do firmware updates on the BaseStation 3200.

    For instructions, refer to the following article/documents:

    Updating the BaseStation 3200 to V12 Firmware with a USB Drive

    Updating the BaseStation 3200 to V16 Firmware with a USB Drive

    Updating the BaseStation 3200 to V17 Firmware with a USB Drive


    When a BaseStation 3200 is connected to the AppManager server, the firmware version on the BaseStation 3200 is compared to the version on the server. If a newer firmware version is available, you can update the BaseStation 3200 from AdminManager.

    1.  In the AdminManager submenu, click Manage BaseStation 3200s. The Manage BaseStation 3200s page displays.

    2.  Click in the row for the BaseStation 3200 that you want to update the firmware on. The controller information displays in a slide-out pane.

    3.  Click the Firmware Updates header row to expand the section if necessary. The Current Version field shows the version of firmware that is running on the controller. If a firmware update is available, the version displays in the Available Version field.

    4.  To update the firmware, click Update in the Available Version row. The firmware update is applied to the BaseStation 3200 controller. It may take several minutes for the firmware update to complete.

    Note

    Disregard the Custom Version field unless Baseline Support directs you to enter a custom firmware ID.


    5.  Click <BACK in the upper-left corner of the slide-out pane to return to the Manage BaseStation 3200s page.

    6.  Click in the row for the BaseStation 3200 that you updated the firmware on. The controller information displays in a slide-out pane.

    7.  Verify that the new firmware version displays in the Current Version field. If the firmware did not update as expected, please call Baseline Support at 866-294-5847.


    Caution 

    If you have a self-hosted Baseline server, contact Baseline Support before updating the BaseStation 3200 firmware. Baseline Support Toll-Free Phone Number: 866.294.5847



    Firmware Version Description  Compatibility   Update Path   Notes
    12.34

    DOWNLOAD
    Current legacy version

    BaseManager, FlowStation V1, SubStation V1

    Update to V16.6 before going to a higher version 

    Choose the correct V16.6 version for the hardware version on your controller

    If updating from V12.29 or earlier, you must first update to V12.34

    16.6 for Hardware Versions 2.0 and lower

    DOWNLOAD

    Current V16 version for Hardware Versions 2.0 and lower

    Includes bug fixes and support for the automatic security updater


    AppManager
    BaseManager
    PipeView
    FlowStation App
    FlowStation V2 SubStation V1.2

    Controllers with Hardware Versions 2.0 and lower cannot be updated to V17

    They can continue to run on V16


    TRC remote controls do not operate with BaseStation 3200 controllers that have been updated to V16.

    When updating from V12.34, all zones move to Mainline 1. Map out all zone-to-mainline assignments prior to updating to V16. Reassign the zones to each individual mainline following the update. Refer to Assigning Zones to Mainlines in the BaseStation 3200 User Manual.

    Export a Program Summary before updating. Refer to Exporting Controller Data in the BaseStation 3200 User Manual.

    16.6 for Hardware Versions 3.0 and higher

    DOWNLOAD

    Current V16 version for Hardware Versions 3.0 and higher

    Includes bug fixes and support for the automatic security updater


    AppManager
    BaseManager
    PipeView
    FlowStation App
    FlowStation V2 SubStation V1.2

    Update directly to V17 or continue on V16

    TRC remote controls do not operate with BaseStation 3200 controllers that have been updated to V16.

    When updating from V12.34, all zones move to Mainline 1. Map out all zone-to-mainline assignments prior to updating to V16. Reassign the zones to each individual mainline following the update. Refer to Assigning Zones to Mainlines in the BaseStation 3200 User Manual.

    Export a Program Summary before updating. Refer to Exporting Controller Data in the BaseStation 3200 User Manual.

    17.0
    DOWNLOAD

    Enhanced security features

    Ability to have security updates automatically pushed to the controller without a firmware update

    AppManager
    BaseManager
    PipeView
    FlowStation V3
    SubStation V2


    If updating from V12.34, you must first update to V16.6

    Controllers with hardware version 3.0 and higher are compatible with V17


    BaseStation 3200 v18.2
    DOWNLOAD

    Cloud Network Module v1.3
    DOWNLOAD

    Improved performance with FlowStation, SubStation, and BaseManager. Enables support for the Baseline Precip Sensor.

    1.  Numerous bugs fixed

    a.  Incorrect controller statuses displayed in BaseManager and AppManager

    b.  FlowStation and SubStation networking disconnects and communication errors

    c.  Delayed or missed water allocations could cause irrigation interruptions

    2.  Support for Baseline Precip Sensor technology


    BaseStation 3200 V17
    For the Cellular Communication optimization to work, you will need to update the BaseStation 3200 to v18.2 and update your Cloud Network Module to v1.3. To do so, simply take a blank USB drive and upload both files (v18.2 and v1.3) onto the drive. Plug the USB into the BaseStation 3200 and power-cycle the controller. As the controller reboots, it will automatically update to the newest firmware for both devices.




    BaseStation 1000


    Read me first, before updating

    Baseline is proud to produce world-class irrigation control products. We're constantly adding new features and improving existing products.  Firmware updates are always free, as long as your hardware is compatible.  Check back often to see what's new!

    Note

    The BaseStation 1000 must have firmware version 1.25 or higher in order to communicate with the Cloud Network Module.


    Update instructions can be found here:
    Updating the Firmware from a USB Drive


    When a BaseStation 1000 is connected to the AppManager server, the firmware version on the BaseStation 1000 is compared to the version on the server. If a newer firmware version is available, you can update the BaseStation 1000 from AdminManager.

    1.  In the AdminManager submenu, click Manage BaseStation 1000s. The Manage BaseStation 1000s page displays.

    2.  Click in the row for the BaseStation 1000 that you want to update the firmware on. The controller information displays in a slide-out pane.

    3.  Click the Firmware Updates header row to expand the section if necessary. The Current Version field shows the version of firmware that is running on the controller. If a firmware update is available, the version displays in the Available Version field.

    4.  To update the firmware, click Update in the Available Version row. The firmware update is applied to the BaseStation 1000 controller. It may take several minutes for the firmware update to complete.

    Note

    Disregard the Custom Version field unless Baseline Support directs you to enter a custom firmware ID.


    5.  Click <BACK in the upper-left corner of the slide-out pane to return to the Manage BaseStation 1000s page.

    6.  Click in the row for the BaseStation 1000 that you updated the firmware on. The controller information displays in a slide-out pane.

    7.  Verify that the new firmware version displays in the Current Version field. If the firmware did not update as expected, please call Baseline Support at 866-294-5847.



    Firmware Version  Description  Notes 
    BaseStation 1000 v1.26
    DOWNLOAD

    Cloud Network Module v1.3
    DOWNLOAD


    AG-1000 v1.19
    DOWNLOAD

    BaseStation 1000 Firmware v1.26

    Communication performance optimized for LTE cellular networking

    AG-1000 Firmware v1.19

    Supports continuous program sets

    For the Cellular Communication optimization to work, you will need to update the BaseStation 1000 to v1.26 and update your Cloud Network Module to v1.3. To do so, simply take a blank USB drive and upload both files (v1.26 and v1.3) onto the drive. Plug the USB into the BaseStation 1000 and power-cycle the controller. As the controller reboots, it will automatically update to the newest firmware for both devices.





    SubStation


    Read me first, before updating

    We always recommend that you perform a system backup before you update the SubStation firmware. If you experience issues with the firmware update, you can restore your SubStation to the previous configuration.

    Additionally, we recommend that you use a USB drive to do firmware updates on the SubStation. Refer to the instructions in this article:

    Updating the Firmware from a USB Drive



    Firmware Version  Description  Compatibility  Notes
    1.0
    DOWNLOAD
    Initial release BaseStation 3200
    V12.30 - 12.34
    If the connected BaseStation 3200 is staying on the V12 firmware, the SubStation must remain on this firmware version.
    1.2
    DOWNLOAD
    Support for the BaseStation 3200 V16 firmware     BaseStation 3200
    V16.1 - 16.6
    If the connected BaseStation 3200 is staying on the V16 firmware, the SubStation must remain on this firmware version.
    2.0
    DOWNLOAD
    Enhanced security features     BaseStation 3200
    V17 higher
    If the connected BaseStation 3200 is updated to the V17 firmware, the SubStation must be updated to this firmware version.
    SubStation v2.4
    DOWNLOAD

    Cloud Network Module v1.3
    DOWNLOAD
    Communication performance optimized for LTE cellular networking
    Support for Baseline Precip Sensor.
    BaseStation 3200
    V17.3 - V18.00
    For the Cellular Communication optimization to work, you will need to update the SubStation to v2.4 and update your Cloud Network Module to v1.3. To do so, simply take a blank USB drive and upload both files (v2.4 and v1.3) onto the drive. Plug the USB into the SubStation and power-cycle the controller. As the controller reboots, it will automatically update to the newest firmware for both devices.

    To communicate with a BaseStation 3200 using Precip Sensor the BaseStation 3200 must be updated to v18.0 firmware or higher.




    FlowStation


    Read me first, before updating

    We always recommend that you perform a system backup before you update the FlowStation firmware. If you experience issues with the firmware update, you can restore your FlowStation to the previous configuration.

    Additionally, we recommend that you use a USB drive to do firmware updates on the FlowStation. Refer to the instructions in this article:

    Updating the Firmware from a USB Drive



    Firmware Version Description Compatibility Notes
    1.0
    DOWNLOAD
    Initial release

    BaseStation 3200 V12.29 and earlier V12.30 - 12.34


    If the connected BaseStation 3200 is staying on the V12 firmware, the FlowStation must remain on this firmware version.    
    2.0
    DOWNLOAD

    Support for the new flow model. Support for PipeView and the FlowStation App


    BaseStation 3200 V16.1-16.6
    PipeView
    FlowStation App


    If the connected BaseStation 3200 is staying on the V16 firmware, the FlowStation must remain on this firmware version.
    3.0
    DOWNLOAD
    Enhanced security features

    BaseStation 3200 V17 and higher
    PipeView
    FlowStation App

    If the connected BaseStation 3200 is updated to the V17 firmware, the FlowStation must be updated to this firmware version.    
    FlowStation v3.8
    DOWNLOAD

    Cloud Network Module v1.3
    DOWNLOAD
    Communication performance optimized for LTE cellular networking

    BaseStation 3200 V17 and higher


    For the Cellular Communication optimization to work, you will need to update the FlowStation to v3.8 and update your Cloud Network Module to v1.3. To do so, simply take a blank USB drive and upload both files (v3.8 and v1.3) onto the drive. Plug the USB into the FlowStation and power-cycle the controller. As the controller reboots, it will automatically update to the newest firmware for both devices.