A Manager Station Low Flow alert occurs when the total combined value of all active stations drops below the Station Low Flow threshold. An alert will be raised for a single OptiFlow XR, or for Manager and Member controllers in an OptiFlow Group. A Manager Station Low Flow alert requires flow sensing capabilities for the POC on the mainline.
Possible Causes
- Clogged heads
- Pump station malfunction
- Valve or master valve not fully opening
Possible Fixes
- Repair any valve issues
- Repair any local pump issues
- Ensure proper supply pressure
Clearing a Station Low Flow Alert from the controller:
1. Press ALERTS.
2. Press à until VIEW FLOW STATUS screen displays.
3. Press * to clear the alert.
Clearing a Station Low Flow Alert from WeatherTRAK Central:
1. Hover over the Alerts tab and click on Alert List. A list of all active alerts will display.
2. Place a checkmark next to the alert you would like to clear.
3. Press the Clear Flow and Electrical Alerts button. A pop-up screen displays asking you to verify the change. Click Yes.