Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    Zone Shutdown High Flow Variance

    Messages & Alerts

    PDF es:

    Info, impact, causes, and troubleshooting a "Zone Shutdown High Flow Variance" message.

    Common Causes 

    • Broken or missing sprinkler head. 
    • Damaged lateral line for the valve.  
    • Incorrect learned flow. 

    What Happens Now? From the alert message:

    • Zone 13 has been shut down because the controller has identified this zone as a source of high flow and will not water again until message is cleared.
    • Flow Variance Threshold (measured in %) is set to allow a 20% variance, bthe controller detected a 25.1%. 
    • Expected vs. Actual Flow (measured in Gallons per Minute (GPM)) are given. The controller expected a 41 GPM but only measured 51.3 GPM.

    Troubleshooting 

    • Repairing any broken sprinkler heads or damaged lateral line. 
    • If you suspect a learn flow value is incorrect, re-learn flow for that zone. 
    • Once the issue is resolved, clear the message to allow irrigation to resume. 

    Learning Flow

    • BaseManager  Zone Assignment
    • Controller or through BaseManager Live View Zone Learn Flow (or Program Learn Flow, if it applies).
    • BaseManager Maps and select Learn Flow for individual zones.