⚠️ Security Notice: Helpjuice, the host of the HydroPoint KnowledgeBase was briefly affected by a third-party security incident between Aug 11, 22:26 UTC and Aug 12, 11:04 UTC. If you visited during that window and were prompted to run a "verification command," please read this article and take action.
Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    (CLK) Catastrophic Leak

    OptiFlow Alert

    PDF es:

     


     

     

    When a catastrophic leak alert occurs, flow has exceeded the catastrophic leak and evaluation time thresholds during non-irrigation hours.

     


    Possible Causes

    • Someone is using a quick coupler or hose bib.

       
    • A valve is not closing completely and is leaking.

       
    • A mainline fitting has a crack and is leaking.

       
    • A quick coupler is stuck partially open or a hose bib has been left open.

     


     

    Possible Fixes

    • Repair any valves, quick couplers or hose bibs.

       
    • Prevent the unauthorized use of a quick coupler or hose bib.

       

    Clearing a Catastrophic Leak Alert

    The alarm doesn’t have a clearing function. The alarm is cleared automatically when there is no leak present.