    Setting No Flow Threshold and Delay

    WeatherTRAK ET Pro3 & LC+

    PDF es:

    The No Flow Threshold is intended to notify a user if a pump station fails, the backflow device has been shut-off, a remote control valve fails to open, or if an isolation valve in the mainline has been turned off. Set the No Flow Threshold at least 15% lower than the station with the lowest flow value.

    1.  Press the FLOW button.

    2.  Press the à button until the SELECT FLOW OPTION screen displays.

    3.  Press the + or button to select Mainlines.

    4.  Press the à button until the NO FLOW THRESHOLD screen displays.

    5.  Press the à button to underline the GPM value. 

    6.  Press the + or button to increase or decrease the factory default value of 5 GPM.

    7.  Press the à button to select the delay period. Press the + or button to change the value.