    BL-5224R biCoder Installation Guide

    Conventional Wired: BL-5224R Series Powered biCoder

    PDF es:

    Each terminal of the Baseline’s Powered biCoder has a serial number which is used as an address to identify it to the BaseStation controller. The BaseStation broadcasts a message along the two-wire and the biCoder responds by turning the attached valve on or off.



    Powered biCoder Installation Instructions

    1.  Copy the programming information from your old clock. Use the worksheet found in the appendix of your controller user manual to make this process easier.

    2.  After you have finished copying the programming information, disconnect valve wires (one at a time) from your clock, making sure to indicate which wire belongs to which zone. (Masking tape works well for this.)

    3.  Connect the valve wires to the valve terminals on the Powered biCoder, writing down which valve and zone is being attached to which terminal.

    Note

    Wire connections must be 3M™ DBR/Y-6 or equivalent moisture-resistant connectors. Install all connections according to the manufacturer’s instructions.


    4.  If you are using biSensors, connect the valve wiring for the zones where the sensors are located to terminals A1, A2, B1, or B2.

    5.  If you are using two-wire, connect it to the two-wire terminals.

    6.  Configure your system according to the configuration section in your controller user manual.

    7.  Power up the controller and verify that the LEDs on the front panel are lit.



    BL5224 24 Valve Powered biCoder 

    (The 12 Valve Powered biCoder has only A1 - A12 terminals populated. The 36 & 48 Valve Powered biCoder incorporates a second BL5224 PCA.)




    biSensor Installation Instructions

    1.  Install the biSensor near the closest valve location. Follow the “Burying the biSensor” instructions included with the biSensor.

    2.  Connect the red wire from the biSensor to the power wire or pilot wire of the valve and black wire from the biSensor to the common wire of the solenoid using the provided 3M™ DBR/Y-6 or equivalent moisture-resistant connectors. It is critical that polarity be maintained.

    3.  Connect the pilot wire from the valve to either the A1, A2, B1, or B2 terminals on the controller.

    4.  Press the biSensor update button and verify that the light above the terminal (A1, A2, B1,or B2) stays on.

    5.  Assign the biSensor and test its operation according to the instructions in the controller’s user manual.