Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    Pump Start/Stop biCoder Installation Guide

    BL-5201PR Valve biCoder

    PDF es:

    Instructions for Using the BL-5201PR to Turn On a Pump Relay
    Activating a Normally Open Relay

    The BL-5201PR biCoder can also be used for the following:

    • Turn off a relay
    • Open a switch
    • Close a switch
    • Refer to the instructions on the back page for installation instructions for these alternate uses.

    Note: Ensure Principle Splicing techniques. Polarity matters! All connections must have 3M™ DBR/Y-6 or equivalent connectors.

    Principle Splicing Techniques

    Delete

    1.  Connect the red and black wires on the biCoder to the red and black wires from the two-wire path that connects to the controller.

    2.  Connect the gray wire from the BL-5201PR biCoder to one wire from the 24VAC transformer.

    3.  Connect the other trasformer wire to the relay.

    4.  Connect the white wire with the black stripe from the BL-5201PR biCoder to the common wire on the relay.

    5.  Cap the gray wire with the black stripe.

    6.  Configure the BL-5201PR in the controller.

    BL-5201PR PUMP START/STOP RELAY biCODER INSTALLATION & WIRING DIAGRAM

    Delete

    References

    HydroPoint Documents - BL_BL-5201PR Pump Start Decoder_Spec Detail.pdf

    BL-5201PR Pump Installation Guide