You can update the details for the flow meter, master valve, and/or pressure sensor that are assigned to a control point.
1. In PipeView, position the hydraulic system diagram so you can see the control point that you want to work with (refer to Using PipeView).
2. Click the control point that you want to work with. The slide-out pane displays.
3. Click Details in the lower-right. The control point details display.
4. Click Edit in the lower-right corner. The control point details are available for editing.
5. If necessary, click the Flow Devices header to expand the section.
6. Find the row for the device that you want to update.
7. In the Description field, type a description that identifies the device.
8. Click in the Enabled field to add or remove the check mark. When a check mark displays in the field, the device is enabled. When the field is empty, the device is disabled and will not be used.
9. Update the specific information for any of the following device:
Flow Meter
K Value: Click the up or down arrows in the field to enter the calibration factor for the flow device that this flow biCoder is connected to.
Master Valve
Normally Open: Click in the field to add or remove the check mark. When a check mark displays in the field, the master valve is normally open. When the field is empty, the master valve is normally closed.
Pressure Sensor
Min Limit: Click the up or down arrows in the field to enter the minimum pressure reading for the connected pressure sensor.
Max Limit: Click the up or down arrows in the field to enter the maximum pressure reading for the connected pressure sensor.
10. Click Save in the lower-right corner.