New in version 3.5, programming a WeatherTRAK Controller can be performed directly from the app. Perform comprehensive Controller programming settings changes that mirror the settings available on WeatherTRAK Central's Controller Program page.
From the Sites List page, use the Select button to reveal the Controller's List page associated with the Site.
From the Controller List page, select the Controller Settings Page button of the Controller that you want to change programming settings for.
From the Controller's Settings page, select the Program tab, to reveal the available options.
Setup
Controller settings found in the Setup section of the Program page on WeatherTRAK Central are available. These might include:
Time Zone
It is important that the correct time zone is set for each Controller
Auto Daylight Savings
If the Controller is located in an area that is affected by Daylight Savings, setting to ON will change the time accordingly
Max Active Stations
Change how many Stations will be physically wired to the Controller.
For example, a 48 station Controller might only have 39 stations and a pump start being operated. Max Active Stations would then be set to 40.
Stack or Overlap (not available for OptiFlow enabled controllers)
Changing this setting determines if Programs found in the Days/Times section have their own independent Water Window and Water Day Mode.
Stacked - Available Programs reference Program A's Water Window and Water Day Mode
Overlap - Available Programs reference their own Water Window and Water Day Mode
MAD Limit Switch
The MAD Limit Switch is a special feature that limits the amount of water being applied to your landscape to make up for maximum allowable depletion levels. When irrigating sports turf, it is often necessary to limit the amount of watering. Using the MAD Limit switch can help you do this. When the MAD limit switch is turned on, the WeatherTRAK controller will never apply more than a 50% depletion during extreme weather conditions. The MAD limit switch is an advanced feature for a special set of users. In most cases, it should be left in the default, or off position.
Runtime Valve Test
When turned to ON to this feature will automatically monitor the system’s wire integrity and report any valve shorts or valve no connects (broken wire) each time the controller irrigates from a scheduled start time.
Backup Weekly ET
If there is a communication issue, for example, that prevents the controller from receiving the daily weather updates for more than 5 days in a row, the controller will then reference this backup value to adjust the ET until communication has been restored. This value should reflect the month with the highest ET and is set to July by default.
Flow
Controller settings found in the Flow section of the Program page on WeatherTRAK Central are available. These might include:
Points of Connection
Assign each available/used POC to a Mainline (ML1, for example). Define the type and function of the POC's Master Valve, Flow Sensor, and Pump Start.
Mainlines
Reference the assigned POC (which acts as a link/button). Define how Mainline Break Alerts, No Flow Alerts, and Leak Alerts function.
Flow Alert Clearing
Change to Auto to have Flow alerts clear each start time. Changing to Manual will require clearing Flow alerts from the Mobile app or Alerts tab in WeatherTRAK Central.
Delay Before Learning
Change between 3 and 10 minutes to allow time for a Station's flow to stabilize prior to learning flow.
Station High Flow Offset %
Change the % amount added to the user-defined flow rate or learned flow rate to determine what the Station’s High Flow Threshold will be. This affects all Stations globally.
Station Low Flow Offset %
Change the % amount subtracted from the user-defined flow rate or learned flow rate to determine what the Station’s Low Flow Threshold will be. This affects all Stations globally.
Excluded Stations is only available on WeatherTRAK Central at this time.
Days/Times
Controller settings found in the Days/Times section of the Program page on WeatherTRAK Central are available. These might include:
Your Controller Series determines the number of Programs that will be displayed. For example, an ET Pro3 has 8 Programs. They are listed as A through H.
Selecting a Program will provide you will additional settings options.
Name
Change the name of the Program
Mainline
Assign the Program to an available Mainline
Pump Start
Define if a Pump Start is Included or Excluded
Water Window 1
Change the Start Time and Duration of the window. The End Time will automatically be determined based on those settings.
If Stacked is selected, this Program A's Water Window will be referenced by all Programs
Water Window 2
Change the Mode to High ET / 2nd Start to make this Water Window available.
Change the Start Time and Duration of the window. The End Time will automatically be determined based on those settings.
If Stacked is selected, this Program A's Water Window will be referenced by all Programs
Water Day Mode
Change to have the Program water on days based on the Mode types below.
- Optimized by WeatherTRAK (default)
- Odd / Even
- Water Day Interval
- Days of Week
- Days of Week by Month
- Off
Select the Options under to change additional settings related to the Mode type.