⚠️ Security Notice: Helpjuice, the host of the HydroPoint KnowledgeBase was briefly affected by a third-party security incident between Aug 11, 22:26 UTC and Aug 12, 11:04 UTC. If you visited during that window and were prompted to run a "verification command," please read this article and take action.
Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    Programming a Direct Connect Master Valve

    WeatherTRAK H2O 2-Wire Controllers

    PDF es:

    Master valves can be programmed for direct connection to ports located on the mini-chassis. See the illustration below for the master valve direct connect locations. 

    1.  Plug the master valve wires into the ports located on the mini chassis board as illustrated above. 

    2.  Press SETUP.

    3.  Press à until CONFIGURE H2O 2-WIRE displays (setup 15).

    4.  Press + or - to select Configure Direct Connect

    5.  Press SELECT to enter. 

    6.  The direct connect screen defaults to configuring direct connect for master valves. Ensure that the screen reads Master, then press à to underline the correct         master valve connection (MV1, MV2, MV3, MV4), as illustrated below.

    Setup: 15
     
    1:56pm
     
    Master               1               2               3               4
     
    Valve                 D1             2W           2W            2W
     
    DI=Direct                      2W=2-Wire
     
    ________
     
    ________
     


    7.  Press + or - to select DI (direct connection). 

    8.  Press RUN to save and exit.