    WeatherTRAK H2O 2-Wire Controllers

    PDF es:

    Master valves can be programmed for direct connection to ports located on the mini-chassis. See the illustration below for the master valve direct connect locations. 

    1.  Plug the master valve wires into the ports located on the mini chassis board as illustrated above. 

    2.  Press SETUP.

    3.  Press à until CONFIGURE H2O 2-WIRE displays (setup 15).

    4.  Press + or - to select Configure Direct Connect

    5.  Press SELECT to enter. 

    6.  The direct connect screen defaults to configuring direct connect for master valves. Ensure that the screen reads Master, then press à to underline the correct master valve connection (MV1, MV2, MV3, MV4), as illustrated below.

    Setup: 15
    1:56pm
    Master               1               2               3               4
    Valve                 D1             2W           2W            2W
    DI=Direct                      2W=2-Wire
    ________
    ________


    7.  Press + or - to select DI (direct connection). 

    8.  Press RUN to save and exit.