    Device Valve Decoder Short Circuit

    Messages & Alerts

    PDF es:

    Info, impact, causes, and troubleshooting a "Device Valve Decoder Short Circuit" message.

    Common causes

    • Issue related to the solenoid or zone wire. 
    • Solenoid may have failed due to a low continuity short. 
    • Solenoid leads could be touching. 
    • Zone wire may be shorted to the common wire.

    What happens now? From the alert message:

    • biCoder serial number: E188171.
    • Zone 12 has a solenoid short preventing operation. 
    • Irrigation for zone 12 will not run.
    • Before troubleshooting:
      • This alert ONLY applies to solenoid side of the biCoder, not the two wire path. 

    Troubleshooting

    • Replace the solenoid or DBR/Y6 splices if needed.
    • Cap off any unused biCoder outputs or extra wires going to a solenoid to prevent shorts.
    • If the zone wire is shorted, use traditional wire repair tools to isolate the short.