Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    FM300 Installation Guide .25" - 2" (OXR & FD-Q)

    Learn how to properly install the FM300 with a .25" to 2" FD-Q Sensor and OXR Data Collector.

    PDF

    Introduction

    This document covers installation for the WC-FM300-US Ultrasonic Flow Monitor for pipe sizes of 1/4 - 2”.

     

    The WaterCompass FM300 Ultrasonic Flow Monitor is a clamp-on flow monitor with a 30 V power supply that connects to the WaterCompass Data Collector.

     

    The monitor sends real-time flow data to the WaterCompass Data Collector that is viewed from the WaterCompass dashboard. Hourly summation of flow data is stored for analysis and reporting.

     

    Contact Information:

    WaterCompass 707-285-3250

    proservices@hydropoint.com

     

    Before you begin, review the safety precautions at the end of this installation guide.

     

    Pre-Configured Settings

    To ensure accuracy, the Flow Monitor will be pre-configured with the following settings:

    • Pipe size (varies)
    • Pipe type (varies)
    • Flow direction (right)
    • K-value (60.1)
     
     

    Materials Provided

    • WaterCompass Data Collector (OXR)
    • WaterCompass Flow Monitor
    • 50' of multi-conductor (3+) shielded plenum rated 18 AWG cable
    • 4 wire nutes
    • 4 Data Collector mounting screws
    • Barrel connector
     
     

    Equipment Needed

    • Philips head screwdriver with long shaft
    • Torx screwdriver (for pipes larger than 2")
    • Lock Nut
    • Zip Ties
    • J-box and fittings
     
     

    Installation Overview