    Troubleshooting and Clearing a Mainline Break (MB) Alert

    WeatherTRAK ET Pro2

    PDF


    If a mainline break has occurred, flow has exceeded the mainline break threshold and the controller will close the station valves.


    Possible Causes:

    • Mainline break: An actual break in the mainline has occurred 
    • Stuck valve: A station valve is stuck on 
    • Programming error: The mainline break threshold is set too low 


    Possible Fixes:


    To clear a Mainline Break from the controller: 

    1.  Turn the Upper Knob to view flow status.

    2.  Press the * button to clear all flow alerts.


    To clear a Mainline Break from WeatherTRAK Central:

    1.  Hover over the Alerts tab and click on Alert List. A list of all active alerts will display.

    2.  Place a checkmark next to the alert you would like to clear.

    3.  Press the Clear Flow and Electrical Alerts button. A pop-up screen displays asking you to verify the change. Click Yes.