Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    Selecting Flow Options for Learning

    WeatherTRAK ET Pro3 & LC+

    PDF es:

    The first task when learning flow is to choose what you would like to monitor. You can choose among Point of Connections, Mainlines, Stations, or Programs.

    1.  Press FLOW.

    2.  Press à until the SELECT FLOW OPTION screen displays.

    3.  Press + or to select Points of Connection.

    4.  Press + or to assign the Point of Connection.

    5.  Press à to assign Master Valve. Options are Off, Normally Open (NO) and Normally Closed (NC). Press + or to choose and underline the desired option.

    6.  Press à to select flow sensor option. Press + or to turn the flow sensor on or off, underlining the desired option.

    7.  Press à to assign a station to a pump start if desired. Press + or to select the desired station.

    8.  Press à to select the mainline. Press + or to select the desired option.

    9.  To select the flow meter size, press to select the size that matches the flow sensor installed. If a flow sensor smaller than 1” is used, then select “Insert-Type” and enter the K and Offset value for the size being used as found in the manufacturer’s installation manual.

    Note

    The flow meter size that is installed in your irrigation system must match the flow meter size that is indicated on the controller.


    10.  Press à to move to the next screen to continue with configuring flow monitoring and learned flow functions.