    Setting Limits for a Control Point

    PipeView: Control Point Settings

    PDF es:

    1.  In PipeView position the hydraulic system diagram so you can see the control point that you want to work with (refer to Using PipeView).

    2.  Click the control point that you want to work with. The slide-out pane displays.

    3.  Click Details in the lower-right. The control point details display.

    4.  Click Edit in the lower-right corner. The control point details are available for editing.

    5.  If necessary, click the Flow Management header to expand the section.

    6.  In the High Flow Limit GPM field, click the up or down arrow to enter the maximum amount of flow in gallons per minute.

    7.  If you want zones (valves) assigned to this control point’s mainline to be stopped and corresponding master valves (MVs) shut off when the flow rate exceeds the limit, click in the Shutdown field to display a check mark. If you do not want excessive flow to shut down the system, click in the Shutdown field to remove the check mark.

    8.  In the Unscheduled Flow Limit GPM field, click the up or down arrow to enter the maximum amount of unscheduled flow in gallons per minute.

    9.  If you want the mainline to be stopped and corresponding MVs to turn off when an unscheduled flow exceeds this limit, click in the Shutdown field to display a check mark. If you do not want excessive flow to shut down the system, click in the Shutdown field to remove the check mark.

    10.  In the High Pressure Limit PSI field, click the up or down arrow to enter the maximum amount of pressure in PSI.

    11.  If you want the mainline to be stopped and corresponding MVs to turn off when the pressure exceeds this limit, click in the Shutdown field to display a check mark. If you do not want excessive pressure to shut down the system, click in the Shutdown field to remove the check mark.

    12.  In the Low Pressure Limit PSI field, click the up or down arrow to enter the minimum amount of pressure in PSI.

    13.  If you want the mainline to be stopped and corresponding MVs to turn off when the pressure drops below this limit, click in the Shutdown field to display a check mark. If you do not want low pressure to shut down the system, click in the Shutdown field to remove the check mark.

    14.  Click Save in the lower-right corner.