Call Us 800.362.8774 Call Us 866-294-5847 Contact Training Training Training WeatherTRAK Login WaterCompass Login AppManager Login

Knowledgebase

    How to Wire a Single Valve Decoder

    H2O 2-Wire: Decoders

    PDF es:

    Note

    If the decoder is not pre-programmed you will need to program it at the controller BEFORE wiring.

    For instructions on how to program a single valve decoder, read Programming a Single Valve Decoder.

    1.  Power off the 2-wire when installing devices. Leave 24 to 36 inches of slack on the 2-wire for ease of use.

    2.  Place the decoder in the valve box. Valves can be located a maximum of 150 ft from the decoder location by using additional 14 gauge wires.

    3.  Wire the valves according to the wiring diagram label on the back of each decoder.

    4.  Connect the red and black wire from the decoder to the corresponding red and black wires on the 2-wire using DBR/Y-6 or equivalent connectors. It is critical that polarity be maintained.

    5.  Using the controller, test the connections. 

    Warning 

    The decoder wires must not have electrical contact with the soil or water. All connections must use DBR/Y-6 or equivalent moisture-resistant connectors. Install all connections correctly. Damage to the system will occur if these specifications are not followed.



    NOTE: The common wires cannot be shared between different decoders.